Added Features
- Added function to delete BACS Logfiles [T2940/T38 and #3368]
- Added function to delete EventLog and DataLog [T92/#3286]
- Added function for BACS Viewer to display Firmwareversion [#687]
- Added delay of BACS Voltage Alarm after a discharge [T2863]
- Added input of multiple IP-adresses in RCCMD Job configuration [T101/#3271]
- Added SNMP OID for total number of modules in alarm or warning on the BACS System system Goldman Sachs [T2903]
- Added: Support of UNMS Emailtraps for the BACS-Screen [T203/#3147]
- Added: At AUX Job 'SensorMan Outlet' now added Logentries for Output Off [T7/#3405]
- Added: BACS Email trap support added [T203/#3147]
- Added: Scheduler implemented [T719/#2351]
- Added: Function to delete BACS Logfiles [T2940]
- Added: configurable delay of BACS Voltage Alarms after a discharge [T2863]
- Added: SNMP OID for total number of modules in alarm or warning on the BACS System [T2903 Goldman Sachs]
- Added: BACS support for 512 Modules and 16 Strings [T2968 + T210/#3149]
Changed Functionality
- Changed: Protocol TOSHIBASEC (Toshiba SEC 9600b) - Add a third option for UPS efficiency value [T2927]
- Changed: Protocol XONL12, AETSER and all other Centralion protocols, now using BT? [T31/#3376]
- Changed: Moved 'About' menu item under 'System' and adjusted layout
- Changed: Removed compatibility Link 'Services/Timeserver'
- Changed: Mitsubishi 2033A,9700 protocol MITSU had startup issues, timeouts increased [T2944]
- Changed: BACS viewer automatic report title changed #3013
- Changed: Multiple IP-Adresses in RCCMD Jobs [T101/#3271]
- Changed: moved 'About' menue under 'System' and adjusted layout
Bug Fixes
- Bugfix: BACS Logfiles rotating did not work, fixed with this version [T2943]
- Bugfix: BACS did not increase Lograte at discharge at FW 1.56, fixed with this version [T2956]
- Bugfix: TOSHIBASEC Overload Alarm not showing up [T2860] and [T2933]
- Bugfix: CS141 does not notify usage of HTTPS to UNMS [T37/#3369]
- Bugfix: SNMP upsAlarmDescriptionID up-count fixed with this version [T2922]
- Bugfix: UPS Alert history transmission through email fixed [T11/#3400]
- Bugfix: SENSORMANAGER Events Analog Input, Digital Inputs alarm off did not work, corrected with this version [T2938]
- Bugfix: Translations corrected [T157/#3199]
- Bugfix: Event configuration now configurable up to 4 hours
- Bugfix: UPS Alert history is now attached to emails [T11]
- Bugfix: SNMP values for AUX States are wrong [T2962]
- Bugfix: Duplicated RCCMD job receivers: regression since [1.56] [T101/T2969]
- Bugfix: At AUX Job 'SensorMan Outlet' now added logentries for "Output-Off" [T7/#3405]
- Bugfix: Events with GETRESULT(#-n) or GETLASTRESULT(#-n) for n!=1 fixed with this version [T2938]
OEM customer specific features, changes and fixes
- ONLINE: Minor changes on new "ZINTO 800 - 3000 VA (Mod.2017)" [T2929]
- Implementation of new "XANTO 6000 - 20000 VA (Mod.2017)" [T2853]
- Bugfix XONL12A - false alarm at SNMP Variable upsAlarmWarningStatus [#3316]
- OEM 070: Minor changes on new UPS-Protokoll UPS Type 12 einbinden [T2908]
- WOEHRLE: Ablerex TAURUS MODBUS protocol MBTAURUS, Disable UPS OFF signal [T359/#2958]
- AEG: Protect 3. M GRIPOW Output Current now corrected in UPS Screen [T2886]
- Protect Plus M600 INVT/MBSALIRM Colors changed at 'On Battery' [T2921]
- Protect Plus M600 INVT/MBSALIRM correcte AutonomyTime Display after Batterytest [T2920]
- PILLER : APOTRANS II values unsigned u. switching voltage problem fixed [T296/#3035]
- AP Premium Adapter-Events [#3403] T9 & T296
- Bugfix APOTRANS_III Events logic [T2874]
- LEGRAND: Megaline ECONT2 Device Functions corrected [T2925]
- TRIMOD Power Modules, Misc Data, Inverter/Booster Temperatures corrected [T2945]
- DK Plus series added with 9600 baud as default [T1830]
- TRIMOD load display over 100% causes wrong autonomytime, corrected [T2942]
- Bugfix for TRIMOD in UNMS, now working with UPSTCP and with SNMP RFC 1628 [T2954]
- ABB: CONCE Alarm Input Bad (XID 618) added to MODBUS Address 120 [T76/#3309]
- SNMP upsAlarmDescriptionID counter corrected [T2922]
- CENTIEL: UPS Events (History) Handling [ID: 10] [T152/#3204]
- ALTERVAC: AETSER via UPS Functions initiated shutdown/restore now fixed [T2906]
- AGIT: KSTAR (Agpower ETX 10-500kVA Modbus) wrong status displayed without batteries, corrected [T2894]
- $$XONL12C: Custom Screen for Agpower C RT 1-10kVA' [T36/#3370]
- $$XONL12B: Custom Screen for 'Agpower D T 10-20kVA' [T218/#3125]
- COROMATIC: Added new UPS models "JBUS Modulys", "JBUS Delphys MX/MP", "JBUS Delphys BC", "JBUS Statys" [T481/- #2779]
- SALICRU: Added Transferswitches "SPS 16 ATS", "SPS 32 ATS" with protocol STSABLER
- Added modular values on INVT/ADAPT-X UPS
- Added SLC-TWIN PRO2 and RT2 series
- KESS: batterX Hybrid USV Implementierung [T256/#3086]
- SNG: New OEM SNG Australia as OEM ID 77, first OEM version 77 release
- MULTIMATIC: Added "MD-XSerie 60-125kVA"
- PowerControl UK: New OEM Powercontrol OEM ID 74, first OEM version 74 release
- KESS: Battery X T256/#3086 fixed
- EATON: MGESHUT at EATON UPS ID319 cause error at UPS functions, fixed
- EFFEKTA: Added CENTRALION Transferswitch as EFFEKTA ATS 16 [T2955]
- INVT: Added modular values
- CET: CE+T private MIB f. Model Agil implemented [T441/#2838]
- ASTRID: Added new UPS-Protocol as UPS Type 12 [T2908]
- CENTIEL: UPS Events (History) Handling [ID: 10] [T152/#3204]